Conductivity Probe

The LIGHTNING MVP is the first quality monitoring system that uses one instrument platform to collect, analyze, and report data from multiple quality indicators including ATP, temperature, pH, and now chemical concentration and conductivity. Results from all parameters are stored in a single database and transferred to a PC for analysis and recordkeeping.

The LIGHTNING MVP incorporates the latest in product innovation including room temperature stable ATP sampling devices and user calibration of all parameters to ensure immediate, accurate monitoring of an organization’s sanitation and HACCP programs. The LIGHTNING MVP Conductivity Probe provides two units of measurement with one probe:
 
Benefits

1. Measurement of Concentration  

                Cost Savings on Expensive Sanitation Chemicals

•  Exact parts-per-million (ppm) reading ensures correct mixing of chemicals.
•  Accurate to within 5%  — 5 times more accurate than test strips and titration kits.
•  Routine mixing at highter than needed concentrations can damage equipment and
   result in thousands of dollars of unnecessary chemical costs.

     Faster, More Accurate Reporting

•  Sanitizer concentration is automatically recorded in MVP database for upload to PC, eliminating manual
   recordkeeping.
•  MVP probe measures concentrations and temperature at the same time, saving time and labor.
•  Perfect for auditing manual and automated chemical dispensing and delivery systems.

     Increased Plant and Food Safety

•  Exact concentration reading ensures chemical solutions are mixed so that they clean and sanitize effectively.
 Advanced algorithms allow for automatic temperature compensation of readings.
•  Probe is safe for food industry use, reusable and requires little maintenance.

 

CONCENTRATION SPECIFICATIONS:
Concentration Range  10 - 200,000 parts-per-million (ppm)
Temperature Range  0° - 100° C
Resolution Temperature 0.1° C / Concentration 1 ppm
Accuracy Temperature ± 0.5°C / Concentration ± 5%
Calibration Single point calibration
Results Concentration/ppm, Temperature, and Pass/Fail
Data Logging 1,000 fully programmable test points
10,000 results stored using Dynamic Memory Allocation (DMA)
Catalog No. 64010-00
Applications Cleaning and Sanitizing chemicals including Quaternary Ammonium, Chlorine, Iodine, and Peracetic Acid

 

 

2. Measurement of Conductivity

      Faster, More Accurate Reporting

•  Conductivity measurements are automatically recorded in MVP database for upload to PC, eliminating manual recordkeeping.

•   MVP probe measures conductivity and temperature at the same time, saving time and labor.

            Increased Plant and Food Safety

  Conductivity measurement of both process controls and CIP rinse water cleanliness provides increased

   adherence to Hygiene and HACCP requirements.

•  Advanced algorithms allow for automatic temperature compensation of readings.

•  Probe is safe for food industry use, reusable and requires little maintenance.

 

CONDUCTIVITY SPECIFICATIONS:
Probe Technology 4-graphite electrode cell design, epoxy body
Conductivity Range 10 - 100,000 microSiemens (mS)
Temperature Range 0° - 100° C
Resolution Temperature 0.1° C / Conductivity 0.1 mS
Accuracy Temperature ± 0.5°C / Concentration ± 5%
Calibration Single point calibration
Temperature Compensation Automatic across entire range
Temperature Coefficient   2.5% / °C Non-selectable
Cell Constant 64010-00
Results   Cleaning and Sanitizing chemicals including Quaternary Ammonium, Chlorine, Iodine, and Peracetic Acid
Data Logging

1,000 fully programmable test points
10,000 results stored using Dynamic Memory Allocation (DMA)

Catalog

64010-00

 

   LIGHTNING MVP:
   System | Instrument | Surface Sampling Device | Liquid Sampling Device | Temperature Probe | pH/temp Probe | MVP TRAX

  © 2004 BioControl