|
| |||
![]()
Conductivity Probe
|
The LIGHTNING MVP™ The LIGHTNING MVP incorporates the latest in product innovation including room temperature stable ATP sampling devices and user calibration of all parameters to ensure immediate, accurate monitoring of an organization’s sanitation and HACCP programs. The LIGHTNING MVP Conductivity Probe provides two units of measurement with one probe: |
| Benefits |
1. Measurement of Concentration
| • Exact parts-per-million (ppm) reading ensures correct mixing of chemicals. |
| • Accurate to within 5% — 5 times more accurate than test strips and titration kits. |
| • Routine mixing at highter than needed concentrations can damage equipment and |
| result in thousands of dollars of unnecessary chemical costs. |
Faster, More Accurate Reporting
| • Sanitizer concentration is automatically recorded in MVP database for upload to PC, eliminating manual |
| recordkeeping. |
| • MVP probe measures concentrations and temperature at the same time, saving time and labor. |
| • Perfect for auditing manual and automated chemical dispensing and delivery systems. |
Increased Plant and Food Safety
| • Exact concentration reading ensures chemical solutions are mixed so that they clean and sanitize effectively. |
| • Advanced algorithms allow for automatic temperature compensation of readings. |
| • Probe is safe for food industry use, reusable and requires little maintenance. |
| CONCENTRATION SPECIFICATIONS: | ||
| Concentration Range | 10 - 200,000 parts-per-million (ppm) | |
| Temperature Range | 0° - 100° C | |
| Resolution | Temperature 0.1° C / Concentration 1 ppm | |
| Accuracy | Temperature ± 0.5°C / Concentration ± 5% | |
| Calibration | Single point calibration | |
| Results | Concentration/ppm, Temperature, and Pass/Fail | |
| Data Logging |
1,000 fully
programmable test points 10,000 results stored using Dynamic Memory Allocation (DMA) |
|
| Catalog No. | 64010-00 | |
| Applications | Cleaning and Sanitizing chemicals including Quaternary Ammonium, Chlorine, Iodine, and Peracetic Acid | |
2. Measurement of Conductivity
Faster, More Accurate Reporting
|
• Conductivity measurements are automatically recorded in MVP database for upload to PC, eliminating manual recordkeeping. |
|
• MVP probe measures conductivity and temperature at the same time, saving time and labor. |
Increased Plant and Food Safety
|
• Conductivity measurement of both process controls and CIP rinse water cleanliness provides increased |
| adherence to Hygiene and HACCP requirements. |
|
• Advanced algorithms allow for automatic temperature compensation of readings. |
|
• Probe is safe for food industry use, reusable and requires little maintenance. |
| CONDUCTIVITY SPECIFICATIONS: | |
| Probe Technology | 4-graphite electrode cell design, epoxy body |
| Conductivity Range | 10 - 100,000 microSiemens (mS) |
| Temperature Range | 0° - 100° C |
| Resolution | Temperature 0.1° C / Conductivity 0.1 mS |
| Accuracy | Temperature ± 0.5°C / Concentration ± 5% |
| Calibration | Single point calibration |
| Temperature Compensation | Automatic across entire range |
| Temperature Coefficient | 2.5% / °C Non-selectable |
| Cell Constant | 64010-00 |
| Results | Cleaning and Sanitizing chemicals including Quaternary Ammonium, Chlorine, Iodine, and Peracetic Acid |
| Data Logging |
1,000 fully
programmable test points |
|
Catalog |
64010-00 |
LIGHTNING MVP:
© 2004 BioControl |